Application of heat meter — RTD platinum resistance

Characteristics:

Following Standards: EN1413 and CJ128-2007

Working Temperature Range: -0℃~ +105℃

Pairing accuracy: ±0.1℃

Measuring Chip: PT1000 (PT500, PT100 is optional)

Materials of Housing : movable M10 brass nut and Φ5 SS304 tube

Material of Cable: 24 AWG OD 4.2mm PVC sheathed cable , two-wire system

Pressure Resistance PN=16bar (flow rate 2m/s)

Curve of Characteristics: TCR=3850ppm/K

Insulation Resistance: follow the standard JB/T8622-1997 Section 5.4

2


Post time: Jun-09-2022